XGN66-12(Z) Box-Type Fixed Metal-Enclosed AC Switchgear
XGN66-12(Z) is indoor 3.6~12kV box-type fixed metal-enclosed AC switchgear for 50Hz three-phase power systems, used for power receiving, distribution, circuit control, protection and monitoring in substations, power plants and mining enterprises.
Featured๏ผ
- Equipped with vacuum circuit breaker as main switch, maintenance-free operation and long service life
- Reliable five-prevention interlock system to prevent misoperation and ensure operator safety
- Independent compartment layout: busbar, circuit breaker, instrument and cable compartments separated by metal partitions
- Reinforced insulation design, sufficient air clearance and creepage distance for stable insulation performance
- Pressure relief window on cabinet top to release overpressure and improve safety under fault conditions
- Compact box-type metal enclosed structure, easy installation, commissioning and routine maintenance
- Wide rated current range from 630A up to 3150A, adaptable for various medium voltage power projects
- Compliant with IEC60298, GB3906, DL/T402 standards and meets indoor substation application requirements
- IP2X protection degree, suitable for indoor installation with altitude โค1000m
XGN66-12(Z) box-type fixed metal-enclosed AC switchgear is indoor medium voltage switchgear designed for 3.6kV~12kV AC 50Hz three-phase single busbar or single busbar sectionalized power system. It undertakes power receiving, power distribution, circuit monitoring and fault protection for power plants, substations and industrial mining projects.
This metal enclosed cabinet is divided into independent functional compartments, including busbar compartment, circuit breaker compartment, instrument compartment and cable compartment. Metal partitions separate each chamber to restrict fault spread and enhance operation safety. It can be fitted with vacuum circuit breakers such as ZN21, VS1, ZN66, ZN28 according to project requirements.
The switchgear adopts reinforced insulation structure with guaranteed air clearance and creepage distance. A pressure relief window is installed at the top of the busbar compartment. When internal arc fault occurs, the pressure can be released through the window to protect operators and cabinet body. The reliable five-prevention interlock mechanism prevents five typical misoperations, greatly improving site operation safety.
The rated current covers 630A to 3150A. The whole cabinet meets IEC and GB standards. It features compact footprint, stable insulation and convenient maintenance. Customers can customize primary circuit schemes, secondary control wiring and internal components according to single-line diagrams. It is an ideal medium voltage power distribution equipment for new substations and power grid upgrading projects.