SC(B)12-30~2500/10 type cast resin dry-type power transformer main Technical parameters
SC(B)12-30~2500/10 type cast resin dry-type power transformer main Technical parameters

SC(B)12-30~2500/10 type cast resin dry-type power transformer main Technical parameters

Iron core

Made up of high quality cold rolled silicon steel sheet that is for electric engineering

Low voltage winding

Made up of a whole copper foil coil

High voltage winding

Made up of sectional type vacuum casting double glass-fiber covered coils

Low voltage terminal

High voltage terminal

Variable wiring mode, which is convenient for installation

Resilient pad

Avoid mechanical resonance, and reduce noise

Clamp and trolley

The wheel of trolley can rotates to 90ยฐ

It is convenient for vertical and horizontal movement.

Packing type resin insulation

With advantages of damp proof, anti-damp and hot, flame-retardant, and self

extinguish.

1

Low local discharge

As the coil is cast in vacuum state, the air bubble produced in coil can be

prevented effciently, the local discharging value fully accords with relative national

standard.

Strong capability of lightning impact

The lightning impact voltage that affects the insulation of transformer windings

along the initial voltage distribution of windings, the foil type windings initial

voltage distribution approaches to linear one, therefore, the transformer

manufactured by us has good ability to resist the lightning impact.

Strong ability to resist short-circuit

The width of copper foil of LV windings that is the reactance height, LV current is

supplied according to be the requirement for ampere turns balance among

windings, HV/LV windings axial force caused by short circuit tends to zero.

Good performance of anti-drying crack

The transformer manufactured by us is made of packing type resin and designed

into the structure of full copper oil, the coefficient of insulation material is the

similar to the that of thermal expansion of copper conductor, so the coils can be

prevented cracking efficiently. The transformer has been done kinds of anti-crack

tests, such as cold/hot alternation test, thermal impact test, rapid aging test, etc,

and the test result demonstrates that our technology can meet the requirements

of service occasions like low temperature, high temperature and large range of

variable temperature, as well as anti-crack after the transformer runs for a long

time.

Strong over-load capability

If the transformers of same capacity whose load consumption is equal, the

sectional area of copper foil will be increased correspondingly, and the volume.